Verotest
About Us   Contact Us   Join Our VeroCycle Club Facebook Group
Leaders in Power Cable Diagnostics & Fault Location
Pressure Testers
  Join Us on Facebook
Easytest 20 kV
Easytest 20 kV
■ Easy to operate
■ Confi gurable test sequences
■ Compact, sturdy and lightweight
■ No polarisation effects
■ Full AC voltage testing
Click to download Download Data/Info Sheet
 
VLF Test System 20 kV
VLF Test System 20 kV
■ The weight of 50 kg make the VLF Test System 20 kV a powerful, universal and at the same time portable unit.
■ The patented change over principle in combination with the recycling of energy stored in the cable capacity results, in comparison to other methods, in a lower weight, less energy consumption and much higher test capacity.
■ The high test capacity of 3 μF permits the simultaneous testing of all three phases.
■ The method is officially recommended by the two VDE Standards 0276-620 and 0276-621.
■ Independent researches shows that VLF test is done most effectively with the 0.1 Hz cosine square wave shape compared to any other VLF wave shape or frequency.
■ VLF is the most economic method for testing PE and
XLPE cables. DC test is not applicable for these cable types.
■ Controlled output voltage
Click to download Download Data/Info Sheet
 
VLF Test systems 28 kV – 60 kV
VLF Test systems 28 kV – 60 kV
Portable test systems to generate 0.1 Hz VLF AC and DC test voltages

■ Two lightweight modules without connecting cables
■ Archiving and programming via chip-card
■ Archiving and comparison of test series with PC software
■ Menu guided operation
■ Test report generated immediately in the field
■ Measurement of leakage current during VLF and DC tests
Click to download Download Data/Info Sheet
 
VLF Sinus 34 kV
VLF Sinus 34 kV
VLF Sine Wave Test System for medium voltage cables

■ High test capacity of 3.5 μF
■ Suitable for outdoor use (IP 67)
■ Single-button operation
■ Integrated safety system
■ Protocolling Continuous duty cycle
Click to download Download Data/Info Sheet
Top of Page
VLF Sinus 54 kV
VLF Sinus 54 kV
VLF sine wave test system for medium-voltage cables

■ High test capacity of up to 5 μF
■ Continuous duty cycle
■ Single-button operation
■ Integrated safety system
■ Suitable for diagnosing 45 kV rated cables
Click to download Download Data/Info Sheet
 
VLF Test System 80 kV
VLF Test System 80 kV
Test with 3 Uo for 46 kV cables as Stand alone or as optional integration for the Centix system.

■ High test power without Frequency reduction
■ No polarisation effects as by DC testing
■ Protocoling by Chipcard or Printer
■ Breakdown recognition
■ Leakage current measurement
Click to download Download Data/Info Sheet
 
HV Tester 25 kV
HV Tester 25 kV
Portable HV Tester

■ Testing of newly installed cables and splices before they are taken into service.
■ Testing disconnected cables.
■ Testing electrical installations.
■ Preventive checks after repairs and work on telecommunication cables and other installations.
Click to download Download Data/Info Sheet
 
AC Voltage Test Set T 22/1
AC Voltage Test Set T 22/1
■ Continuous testing with AC voltages up to 75 kV at 1 kVA.
■ Set composed of function blocks:
- T 22/124 control unit
- T 22/12 SF6 gas transformer
■ Built-in overload protection
■ DC Voltage testing with rectifier attachment.
Click to download Download Data/Info Sheet
Top of Page
AC-DC 25kV-850kV
AC-DC 25kV-850kV
For dielectric testing to VDE 0276 part 1 and for DC testing in high voltage and cables systems

■ Built-in rechargeable battery with integrated charger.
■ Stabilised, continuously adjustable output voltage 0 to 25 kV.
■ Indication of leakage current and test voltage.
■ Integrated discharge unit.
■ Immune to short and open circuit conditions.
Click to download Download Data/Info Sheet
 
HPA 100 AC / HPA 130 DC
HPA 100 AC / HPA 130 DC
Control instruments HSG 10 - 1 are used for controlling the
high voltage transformers of the type HTR 100.

They consist of a variac, test meters for measuring the current
and high voltage, operational components for the high
voltage spark gap, a timer for the test duration and safety
circuit.
Click to download Download Data/Info Sheet
 
T26.1 400 & 650kV DC Tester
T26.1 400 & 650kV DC Tester
The T 26/1A and T 26/1B high-voltage test sets are efficient, mobile systems for high-voltage testing of cables, cable systems and installations as required by current regulations (VDE) with DC voltages of up to 400 kV and 650 kV respectively. The sets are suitable for both installation in measuring trailers and onsite testing as stationary test set.

The spatial separation of the operating and high-voltage units makes it possible to operate the sets from outside the immediate danger area. Their modular structure makes them easy to set up on site and allows adaptation to measuring tasks.
Click to download Download Data/Info Sheet
 
T99.1 40kV DC Tester
T99.1 40kV DC Tester
■ testing the disruptive strength of cables, cable fittings, equipment and installations with max. 40 kV.
■ locating high-impedance and intermittent cable faults in low and medium voltage systems as per the decay method in conjunction
with a time domain reflectometer.
■ converting high-impedance and intermittent cable faults into lowresistance faults (burning).
Click to download Download Data/Info Sheet
Top of Page
TRAINING DATES
 
NEXT SEMINAR
 
LATEST NEWS
           
© Copyright Verotest (Pty) Ltd      email us webdevine.co.za - web design, graphic design, printing, internet, hosting, annual reports, logo design, business card design, web site, web development, email seba kmt products   l   ponovo products   l   other products   l   services   l   workshop   l   training   l   contacts   l   home   l   about